Global Global Algérie Français Algeria English Angola Português Angola English Argentina Español Argentina English Australia English Austria Deutsch Austria English Azerbaijan English Azerbaijan Русский Bahrain English Bangladesh English Belgium English Belgium Français Belgium Nederlands Brazil Português Brazil English Bulgaria български Bulgaria English Cameroon English Cameroon Français Canada English Canada Français Chile Español Chile English China 中文 China 日本語 China English Colombia Español Colombia English Croatia English Czech Republic Čeština Czech Republic English Denmark English Djibouti English Ecuador Español Ecuador English Egypt English Estonia English Ethiopia English Finland Suomi Finland English France Français France English Georgia English Georgia Русский Germany Deutsch Germany English Ghana English Greece Ελληνικά Greece English Guatemala Español Guatemala English Hong Kong, China English Hong Kong, China 中文 Hungary Magyar Hungary English India English Indonesia English Iraq English Ireland English Italy Italiano Italy English Ivory Coast Français Ivory Coast English Japan 日本語 Japan English Jordan English Kazakhstan Русский Kazakhstan English Kenya English Kuwait English Kyrgyzstan Русский Kyrgyzstan English Latvia English Lithuania English Malaysia English Mauritius English Mauritius français (Maurice) Mexico Español Mexico English Moldova Română Moldova English Mongolia English Morocco English Morocco Français Mozambique Português Mozambique English Netherlands Nederlands Netherlands English New Zealand English Nigeria English Norway English Oman English Pakistan English Paraguay Español Paraguay English Peru Español Peru English Philippines English Poland Polski Poland English Portugal Português Portugal English Qatar English Republic of Korea 한국어 Republic of Korea English Romania Română Romania English Saudi Arabia English Serbia Српски Serbia English Singapore English Slovakia English Slovenia English South Africa English Spain English Spain Español Sri Lanka English Sweden English Switzerland Deutsch Switzerland Français Switzerland Italiano Switzerland English Tanzania English Thailand ไทย Thailand English Togo English Togo Français Tunisia English Tunisia Français Türkiye Türkçe Türkiye English Turkmenistan Русский Turkmenistan English Ukraine Українська Ukraine English United Arab Emirates English United Kingdom English Uruguay Español Uruguay English USA English Uzbekistan English Uzbekistan Русский Vietnam Tiếng Việt Vietnam English

REACH Chemical Analysis: A Complete Guide to SVHC Testing and Restricted Substance Compliance

REACH chemical analysis is the systematic laboratory process of detecting, quantifying, and reporting Substances of Very High Concern (SVHC) and restricted chemicals in products placed on the European Union market under Regulation (EC) No 1907/2006. This guide covers the regulatory scope, sample types, testing items, analytical methods, and practical applications of REACH compliance testing for manufacturers, importers, and downstream users worldwide.

Technical Overview

REACH (Registration, Evaluation, Authorisation and Restriction of Chemicals) is the European Union regulation (EC) No 1907/2006, in force since 1 June 2007 and administered by the European Chemicals Agency (ECHA). It is one of the most comprehensive chemical control frameworks in the world, governing the manufacture, import, and placing on the EU market of chemical substances on their own, in mixtures, and in articles. For companies supplying consumer goods, electronics, textiles, toys, or industrial components to Europe, REACH chemical analysis is the primary technical tool for demonstrating that products do not contain regulated substances above legal thresholds.

REACH chemical analysis typically addresses three distinct regulatory mechanisms:

  • SVHC Candidate List screening: The ECHA Candidate List of Substances of Very High Concern, updated approximately twice per year, now contains more than 240 entries. Under Article 33, suppliers of articles containing any SVHC above 0.1% weight-by-weight (w/w) must provide adequate information to customers and, upon request, to consumers. Since January 2021, such articles must also be notified to the SCIP database under the EU Waste Framework Directive.
  • Annex XVII restricted substances testing: Annex XVII lists substances whose manufacture, marketing, and use are restricted or prohibited under specific conditions, such as phthalates in plasticized materials, cadmium in coatings, lead in consumer articles, azo dyes in textiles, nickel release in prolonged skin-contact items, PAHs in rubber and plastic parts, chromium VI in leather, and dimethyl fumarate (DMF).
  • Annex XIV authorisation substances: Substances on the Authorisation List may only be used after specific authorisation or within sunset-date exemptions, which applies mainly to chemical manufacturers and formulators rather than article assemblers.

Because the SVHC list changes frequently and Annex XVII entries are regularly amended, REACH chemical analysis must be repeated or updated periodically to maintain continuous compliance throughout the supply chain.

Testing Samples

REACH chemical analysis is performed on homogeneous materials, meaning each physically distinct part or component with a uniform composition is tested separately. Typical sample matrices include:

Polymers and Plastics

Plastic samples are screened for phthalate plasticizers (DEHP, DBP, BBP, DIBP, DINP, DIDP, DNOP), bisphenol A, short-chain and medium-chain chlorinated paraffins, brominated flame retardants, and the full SVHC Candidate List. Samples are usually cryogenically milled to a fine powder to ensure representative extraction and digestion.

Metals and Metal Alloys

Metallic materials are tested for restricted elements such as lead, cadmium, and hexavalent chromium, as well as SVHC metals and compounds including cobalt, arsenic, antimony, and nickel. Surface coatings and plating layers are analyzed separately from base alloys.

Textiles and Leather

Textile and leather articles are analyzed for azo dyes that may release carcinogenic aromatic amines, formaldehyde, pentachlorophenol, chromium VI (particularly in chrome-tanned leather), DMF, PFAS-based water repellents, chlorinated paraffins, and SVHC content in dyes, finishes, and coatings.

Electronic and Electrical Products

Electrical and electronic equipment is tested for SVHC screening of polymeric and non-metallic parts, often combined with RoHS Directive (EU) 2015/863 testing for lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, polybrominated diphenyl ethers, and the four regulated phthalates.

Coatings, Paints, Inks, and Adhesives

Liquid and cured coating systems are analyzed for restricted phthalates, organotin compounds, chromium VI, cadmium and lead pigments, formaldehyde releasers, and SVHC solvents or additives.

Rubber, Elastomers, and Foam Materials

Rubber components are priority matrices for PAH analysis due to the historical use of extender oils rich in polycyclic aromatic hydrocarbons, along with testing for nitrosamines, organotins, and phthalates.

Ceramics, Glass, and Other Inorganic Materials

Glass and ceramic parts, including crystalline silica-containing materials, are tested for lead and cadmium release, arsenic, and relevant SVHC inorganic substances.

Testing Items

Common REACH chemical analysis test packages include the following items:

  • Full SVHC Candidate List screening (updated to the latest ECHA revision)
  • Phthalates: DEHP, DBP, BBP, DIBP, DINP, DIDP, DNOP, DnHP, DEHA, and related esters
  • Heavy metals and elements: lead, cadmium, mercury, total chromium, arsenic, cobalt, antimony, selenium
  • Polycyclic aromatic hydrocarbons (PAHs): the eight PAHs restricted under Annex XVII entry 50, typically at 0.5 mg/kg for toys and childcare articles and 1 mg/kg for other consumer products
  • Azo dyes releasing any of the restricted carcinogenic aromatic amines (30 mg/kg per amine limit)
  • Organotin compounds: TBT, DBT, MBT, DOT, TPhT
  • Short-chain chlorinated paraffins (SCCPs) and medium-chain chlorinated paraffins (MCCPs)
  • Formaldehyde in textiles and leather
  • Hexavalent chromium (Cr(VI)), including 3 mg/kg limit for leather articles in skin contact
  • Nickel release for prolonged skin-contact articles (0.5 µg/cm²/week)
  • PFOA, PFOS, PFHxS, and related per- and polyfluoroalkyl substances (PFAS)
  • Bisphenol A and other endocrine-disrupting SVHC
  • Brominated flame retardants: HBCDD, decaBDE, TBBPA, and related compounds
  • Dimethyl fumarate (DMF) in products, 0.1 mg/kg limit
  • Cadmium in paints and plastic stabilization, 0.01% limit
  • Lead in consumer articles, 0.05% limit

Testing Methods

REACH chemical analysis relies on a combination of chromatographic, spectrometric, and colorimetric techniques. Samples are first prepared by milling, cutting, or digestion to obtain homogeneous representative portions, then subjected to targeted analytical methods:

  • Gas chromatography-mass spectrometry (GC-MS): Quantification of phthalates, PAHs, organotins, SCCPs, azo dye amines (after reductive cleavage), and semi-volatile SVHC, generally with reporting limits of 5-10 mg/kg.
  • Inductively coupled plasma optical emission spectrometry (ICP-OES) and ICP mass spectrometry (ICP-MS): Determination of elemental metals after acid digestion, including microwave-assisted digestion, with ppm to ppb level detection.
  • Liquid chromatography-tandem mass spectrometry (LC-MS/MS) and HPLC: Analysis of PFAS, bisphenol A, non-volatile SVHC, and formaldehyde derivatives.
  • UV-Visible spectrophotometry: Colorimetric determination of hexavalent chromium and extracted formaldehyde.
  • Ion chromatography: Alternative confirmatory technique for Cr(VI) determination.
  • X-ray fluorescence (XRF) spectrometry: Rapid non-destructive screening of elemental composition before confirmatory wet-chemical analysis.

Frequently referenced method standards include the IEC 62321 series for electrotechnical products (including IEC 62321-5 for lead and cadmium and IEC 62321-8 for phthalates in polymers), EN 1811 for nickel release, EN 14362-1 and EN 14362-3 for azo colorants in textiles and leather, ISO 17075-1 and ISO 17075-2 for chromium VI in leather, EN ISO 14184-1 for formaldehyde in textiles, EN 14372 for phthalates in childcare articles, ISO 8124-3 and EN 71-3 for element migration in toys, and applicable GB standards for goods manufactured in China. Accredited third-party laboratories typically complete standard REACH test packages within five to ten working days, with screening results issued against the most recent SVHC list update.

Applications

REACH chemical analysis supports regulatory compliance and risk management across many industries:

  • Consumer goods and general merchandise: Demonstrating SVHC and Annex XVII compliance for housewares, stationery, jewelry, and lifestyle products sold in the EU.
  • Toys and childcare articles: Verifying restricted phthalates, PAHs, element migration, and formaldehyde limits for products handled by children.
  • Electronics and electrical equipment: Combining REACH SVHC screening with RoHS testing for circuit boards, enclosures, cables, connectors, and batteries.
  • Textiles, apparel, and footwear: Controlling azo dyes, formaldehyde, PFAS finishes, chromium VI in leather, and phthalates in prints and trims.
  • Automotive supply chain: Providing substance declarations and analytical evidence for component and material suppliers to global vehicle manufacturers.
  • Packaging and food contact materials: Supporting combined REACH and EU packaging directive compliance for inks, coatings, and adhesives.
  • Import control and market surveillance: Supplying test reports that respond to EU member state authority requests, customs inquiries, and customer audits.

FAQ

What is the difference between SVHC testing and Annex XVII testing?

SVHC testing screens articles against the ECHA Candidate List with a communication threshold of 0.1% w/w per substance, while Annex XVII testing verifies compliance with legally binding restrictions that specify substances, concentration limits, and conditions of use. Both may be required for the same product.

What does the 0.1% w/w SVHC threshold mean?

The 0.1% weight-by-weight threshold applies to each SVHC in each article, or in each homogeneous material depending on the legal interpretation adopted by EU member states. If exceeded, the supplier must communicate safe use information to professional customers and notify the SCIP database.

How often should SVHC screening be repeated?

ECHA updates the Candidate List approximately twice per year, typically adding new substances each cycle. Responsible suppliers generally re-screen products whenever the list is updated, whenever materials or suppliers change, and at least annually for continuing production.

Is laboratory testing legally mandatory under REACH?

REACH does not always explicitly require chemical testing of articles, but analytical verification by accredited third-party laboratories is the recognized and most defensible way to demonstrate that SVHC and restricted substances are absent or below thresholds, especially when supplier declarations are unavailable.

How much sample is needed for REACH analysis?

Typical requirements are 5 to 20 grams per homogeneous material for organic screening and elemental analysis, or a component of comparable size. For trace SVHC confirmation, additional sample mass improves detection capability and representativeness.

Can REACH testing be combined with other chemical regulations?

Yes. SVHC screening is frequently combined with RoHS, POPs Regulation (EU) 2019/1021, toy safety standards such as EN 71 and ISO 8124, and national requirements including GB standards in China, reducing duplicate sampling and cost.

What should a compliant REACH test report contain?

A valid report should identify the sample and homogeneous materials, state the applicable SVHC list version or Annex XVII entries, list methods and detection limits, report quantitative results against thresholds, and be issued by an ISO/IEC 17025 accredited third-party laboratory.

Why Choose ZKGX?

  • State-of-the-art analytical equipment
  • Highly qualified scientific team
  • Fast turnaround time
  • Competitive pricing